[{"data":1,"prerenderedAt":258},["ShallowReactive",2],{"site-header-common":3,"site-footer-common":59,"site-navigation-common":86,"guidance:measurement-and-trials":113},{"id":4,"extension":5,"footer":6,"meta":50,"navbar":51,"stem":57,"__hash__":58},"common\u002Fcommon.yml","yml",{"tagline":7,"legalTitle":8,"cookieSettingsLabel":9,"links":10,"sections":11},"Acoustic cleaning intelligence for industrial fouling, soot, ash, dust and build-up.","Legal","Cookie preferences",[],[12,24,36,48],{"title":13,"links":14},"Product",[15,18,21],{"label":16,"to":17},"How it works","\u002F#how-it-works",{"label":19,"to":20},"Application fit","\u002F#fit",{"label":22,"to":23},"ROI calculator \u002F Coming soon","\u002F#economics",{"title":25,"links":26},"Applications",[27,30,33],{"label":28,"to":29},"Boilers and heat transfer","\u002Fapplications\u002Fboilers-heat-transfer",{"label":31,"to":32},"SCR catalyst cleaning","\u002Fapplications\u002Fscr-catalyst-cleaning",{"label":34,"to":35},"Dust collection","\u002Fapplications\u002Fdust-collection",{"title":37,"links":38},"Resources",[39,42,45],{"label":40,"to":41},"Blog","\u002Fresources\u002Fblog",{"label":43,"to":44},"Glossary","\u002Fglossary",{"label":46,"to":47},"Buyer's guide","\u002Fresources\u002Fblog\u002Facoustic-cleaning-system",{"title":8,"links":49},[],{},{"links":52,"action":56},[53,55],{"label":25,"to":54},"\u002F#applications",{"label":16,"to":17},{"label":22,"to":23},"common","rzKP9GVWGTSjN3RTtCIYeR1oX7iQIvlngM7hHP108rc",{"id":4,"extension":5,"footer":60,"meta":80,"navbar":81,"stem":57,"__hash__":58},{"tagline":7,"legalTitle":8,"cookieSettingsLabel":9,"links":61,"sections":62},[],[63,68,73,78],{"title":13,"links":64},[65,66,67],{"label":16,"to":17},{"label":19,"to":20},{"label":22,"to":23},{"title":25,"links":69},[70,71,72],{"label":28,"to":29},{"label":31,"to":32},{"label":34,"to":35},{"title":37,"links":74},[75,76,77],{"label":40,"to":41},{"label":43,"to":44},{"label":46,"to":47},{"title":8,"links":79},[],{},{"links":82,"action":85},[83,84],{"label":25,"to":54},{"label":16,"to":17},{"label":22,"to":23},{"id":4,"extension":5,"footer":87,"meta":107,"navbar":108,"stem":57,"__hash__":58},{"tagline":7,"legalTitle":8,"cookieSettingsLabel":9,"links":88,"sections":89},[],[90,95,100,105],{"title":13,"links":91},[92,93,94],{"label":16,"to":17},{"label":19,"to":20},{"label":22,"to":23},{"title":25,"links":96},[97,98,99],{"label":28,"to":29},{"label":31,"to":32},{"label":34,"to":35},{"title":37,"links":101},[102,103,104],{"label":40,"to":41},{"label":43,"to":44},{"label":46,"to":47},{"title":8,"links":106},[],{},{"links":109,"action":112},[110,111],{"label":25,"to":54},{"label":16,"to":17},{"label":22,"to":23},{"id":114,"title":115,"body":116,"description":235,"extension":236,"eyebrow":237,"meta":238,"navigation":239,"path":240,"primary":241,"relatedLinks":242,"seo":249,"stem":252,"summary":253,"__hash__":257},"guidance\u002Fguidance\u002Fmeasurement-and-trials.md","Measurement and trial guide",{"type":117,"value":118,"toc":223},"minimark",[119,124,128,131,135,138,141,145,148,173,176,180,183,186,190,193,196,200,203,207,210,213,217,220],[120,121,123],"h2",{"id":122},"begin-with-a-decision","Begin with a decision",[125,126,127],"p",{},"State what the evaluation must establish. A useful question is specific: can preventive acoustic cleaning hold this zone near an agreed condition for a representative operating campaign while the existing removal system continues to function?",[125,129,130],{},"Do not begin with a broad promise to improve uptime or efficiency. Select the plant signal that the diagnosed deposit directly affects.",[120,132,134],{"id":133},"establish-the-starting-condition","Establish the starting condition",[125,136,137],{},"Record whether the surface begins clean, partially recovered or already restricted. A preventive system should not be judged as though it were designed to remove mature slag, hardened deposits or packed material.",[125,139,140],{},"Document the cleaning method used to create the baseline and preserve inspection photographs with date, scale and location.",[120,142,144],{"id":143},"select-one-primary-metric","Select one primary metric",[125,146,147],{},"Examples include:",[149,150,151,155,158,161,164,167,170],"ul",{},[152,153,154],"li",{},"differential pressure across the affected zone;",[152,156,157],{},"flue-gas or process exit temperature at comparable operation;",[152,159,160],{},"fan load or available flow margin;",[152,162,163],{},"cleaning cycles or manual interventions per operating period;",[152,165,166],{},"hopper discharge interruptions;",[152,168,169],{},"campaign length before derate or cleaning;",[152,171,172],{},"catalyst, field or collection stability linked to the affected deposit.",[125,174,175],{},"Secondary metrics can provide context, but they should not replace a predefined primary measure after results are known.",[120,177,179],{"id":178},"define-comparable-conditions","Define comparable conditions",[125,181,182],{},"Record load, production rate, fuel, feedstock, reagents, gas flow, temperature, moisture, ambient conditions and operator interventions. Identify maintenance or control changes that occur during the comparison.",[125,184,185],{},"Normalisation may be required where operating conditions vary. The method should be agreed before the data is reviewed.",[120,187,189],{"id":188},"set-the-measurement-period","Set the measurement period",[125,191,192],{},"The period should cover the cycle over which the deposit normally returns and include representative operating variation. A brief clean period cannot establish sustained prevention if the historical problem develops over weeks or months.",[125,194,195],{},"State required data completeness and the treatment of outages, sensor faults and abnormal operation.",[120,197,199],{"id":198},"inspect-the-material-path","Inspect the material path",[125,201,202],{},"Confirm that material leaves the affected zone and reaches the intended hopper, screw, conveyor or ash system. Track re-entrainment, downstream loading and new accumulation locations.",[120,204,206],{"id":205},"agree-success-and-stop-criteria","Agree success and stop criteria",[125,208,209],{},"Success should state the primary metric, threshold, duration and acceptable operating conditions. Stop criteria should cover adverse pressure, emissions, vibration, noise, downstream overload, equipment condition and any site-specific safety concern.",[125,211,212],{},"The existing cleaning system should remain available unless the approved test plan states otherwise.",[120,214,216],{"id":215},"preserve-the-evidence-status","Preserve the evidence status",[125,218,219],{},"Label each eventual result as Sylio measured, customer confirmed or independently verified. Record configuration, firing sequence, maintenance, tuning and anything that did not improve. This prevents one result from becoming a universal claim.",[125,221,222],{},"Sylio does not currently promise a trial through this page. Commercial and operational trial availability must be confirmed separately.",{"title":224,"searchDepth":225,"depth":225,"links":226},"",2,[227,228,229,230,231,232,233,234],{"id":122,"depth":225,"text":123},{"id":133,"depth":225,"text":134},{"id":143,"depth":225,"text":144},{"id":178,"depth":225,"text":179},{"id":188,"depth":225,"text":189},{"id":198,"depth":225,"text":199},{"id":205,"depth":225,"text":206},{"id":215,"depth":225,"text":216},"Define a clean baseline, representative comparison, primary metric and stop criteria before evaluating an acoustic-cleaning application.","md","Guidance \u002F Verification",{},true,"\u002Fguidance\u002Fmeasurement-and-trials",null,[243,246],{"label":244,"to":245},"Evidence checklist","\u002Fguidance\u002Fevidence-checklist",{"label":247,"to":248},"ROI and payback guide","\u002Fresources\u002Fblog\u002Facoustic-cleaning-roi-payback",{"title":250,"description":251},"Acoustic cleaning measurement and trial guide","Plan a baseline, metric, representative measurement period, inspection and stop criteria for an industrial acoustic-cleaning evaluation.","guidance\u002Fmeasurement-and-trials",[254,255,256],"Choose one primary metric that matches the diagnosed deposit location.","Record load, fuel, feed, ambient and process changes that could explain the result.","Trial availability is not yet established; use this protocol to define evidence, not to request a promised pilot.","ztwTI-DrYOaOJbIKtKC5Z3xDN3U2Vh_zaCyUB1HCo4E",1784218412191]